Nº d'article
{{item.ItemCode}}
code EAN
{{item.ItemVariation.EANCode ? item.ItemVariation.EANCode : item.EANCode}}
Pourcentage de TVA
{{item.VATPercentage}}%
la marque
{{item.ItemBrandDescription}}
Numéro de fabricant
{{item.SupplierCode}}
Code fournisseur de l'article
{{item.ItemSupplierCode}}
Taille de l'emballage
{{item.PackSize}}
Suitable for food production
For non-perishable foods only
Min. Fe-particle size that can be caught
0,03 mm
Production stop required during ferrous particles disposal
Yes
Cleaning (ferrous particles disposal) method
Manual
Ferrous particles disposal via
Manually taking out magnets + pulling them out of extractor
Product inlet size
520x300 mm
Product outlet size
520x300 mm
Interface connection type/size
Rectangular flanges with hole pattern acc. to drawing
Electrical connection
To connection box
Number of magnetic rotors
2
Materials in contact with product
AISI316 (SS 1.4401) / AISI316L (SS 1.4404)
Material seal between housing and door/magnet unit
Silicone VMQ, 40° Shore, EC1935/FDA, red
Motor oil: food grade
Yes
Surface finishing (interior/exterior)
S1: Grit blasted, Ra 3 µm
Extra wear-resistant coating
No
Welds inside the product channel
Wm: Continuously welded
Welds outside the product channel
Wm: Continuously welded where possible
Max. operating temperature
60 °C
Min./max. ambient temperature
-20 to 40 °C
Magnetic system
Magnetic bar in extractor tube
Magnet quality
Neodymium N-42
Magnetic bars position / behaviour during production
Rotating, magnetic bars placed in 2 rotors
Magnetic bar size
Extractor tube Ø25 mm; magnetic bar Ø23 mm
Number of magnetic bars
2x12
Flux density on (internal) magnetic bar (±10%)
10700 gauss
Flux density on magnet tube in contact with product (±10%)
8000 gauss
Motor drive
SEW electro motor with gear box
Motor current
1,82 (Δ) / 1,05 (Y) A
Motor voltage
230 (Δ) / 400 (Y) V AC
Motor rotational speed (out)
36 rpm
Motor dust/water protection class
IP65
Incl. double seal with air purging on shaft (max. 0.1 bar)
Yes
Incl. all bars magnet in/out sensoring
No
Safety device between housing and door/magnet unit
Switch (key type, Steute AZ16-zvk, Ex II 2GD)
Potential-free contact for ‘door closed’ signal
250 V AC max., 230 V DC max.
Potential-free contact for ‘motor on’ signal
600 V AC max., 250 V DC max.