Número de artículo
{{item.ItemCode}}
Código EAN
{{item.ItemVariation.EANCode ? item.ItemVariation.EANCode : item.EANCode}}
Porcentaje de IVA
{{item.VATPercentage}}%
Marca
{{item.ItemBrandDescription}}
Código del correo del artículo
{{item.ItemSupplierCode}}
Tamaño del paquete
{{item.PackSize}}
Min. Fe-particle size that can be caught
0,1 mm
Production stop required during ferrous particles disposal
Yes
Cleaning (ferrous particles disposal) method
Automatic
Ferrous particles disposal via
Pneumatically actuated valve box underneath product channel
Outlet shape
Round (product) / Square (FE-parts)
Product inlet size
Ø500 mm
Product outlet size
Ø500 mm
Ferrous particles outlet size
500x340 mm
Inlet interface connection type/size
DN500 acc. DIN 24154 R4
Outlet interface connection type/size
DN500 acc. DIN 24154 R4
Pneumatic connection
For 6 mm hose
Electrical connection
To connection box
Adjustable fasteners on cleaning/inspection door
Yes
Materials in contact with product
Steel / AISI316 (SS 1.4401) / Nickel plated steel
Material seal between housing and door/magnet unit
Silicone sponge rubber VMQ, white
Surface treatment/finishing
Painted
Extra wear-resistant coating
No
Welds inside the product channel
WB: Welded shut
Welds outside the product channel
WB: Welded shut
Colour housing
Grey (Platinum grey): RAL7036
Colour door
Dark grey (Umbra grey): RAL7022
Max. operating temperature
80 °C
Max. operating temperature in ATEX environment
40 °C
Min./max. ambient temperature
-20 to 40 °C
ATEX marking
Ex II 1/2 D T130 °C
Suited for use in ATEX zone
20, 21 and 22 inside, 21 and 22 outside
Dust/water protection class
IP54
Magnetic system
Electromagnet
Magnet field strength (flux density) (±10%)
2400 gauss
Pneumatic supply
6 - 8 bar
Duty cycle
100%, as long as product is flowing through (cooling effect)
Associated control unit (not included)
ESBP310003
Remark Control
This machine has to be ordered with mentioned control unit
Including integrated valve box for Fe-particles disposal
Yes
Thermistor signals
120 °C (warning) and 130 °C (shut off)
Safety device between housing and door/magnet unit
Coded magn switch (Telemecanique XCSDMC59010EX) (Ex II2D)